User Tools

Site Tools


a1:protocol:rpr_rplc_insta_hot

This is an old revision of the document!


Repair/Replace Insta-Hot

REPAIR

  1. IDENTIFY IF UNIT IS PLUGGED IN OR NOT
  2. ENSURE 120V IS PRESENT AT OUTLET
  3. ENGAGE WATER SUPPLY AND CHECK TEMP SETTING
  4. IF UNIT IS SPITTING WHILE ENGAGED, TYPICALLY THERE IS A HOLE IN THE INTERNAL TANK AND IT SHOULD BE REPLACED.
  5. IF LEAKING AT SPOUT, CHECK O-RINGS AT SPOUT CONNECTION.

REPLACEMENT

  1. UNPLUG UNIT/TURN POWER OFF.
  2. TURN OFF WATER SUPPLY TO UNIT
  3. ON SS UNIT, UN CLIP AND DETACH ALL 3 LINES TO TO OF UNIT. THIS CAN VARY ON DIFFERENT INSTA HOT MODELS. I.E; FRANKE, LIL BUTLER ETC.
  4. REMOVE UNIT AND REPLACE WITH SAME UNIT.
  5. ATTACH AND HANG NEW TANK.
  6. ATTACH OLD 3 WATER LINES FROM EXISTING SPOUT TO TANK.
  7. TURN WATER BACK ON AND FILL TANK WITH PURE STREAM COMING OUT OF SPOUT TO CLEAR OUT ANY AIR.
  8. PLUG UNIT IT/TURN ON POWER - THIS IS DONE AFTER FILLING TO PREVENT DRY FIRE OF UNIT.
a1/protocol/rpr_rplc_insta_hot.1608827535.txt.gz · Last modified: 2020/12/24 08:32 by davek