a1:protocol:rpr_rplc_insta_hot
This is an old revision of the document!
Table of Contents
Repair/Replace Insta-Hot
REPAIR
- IDENTIFY IF UNIT IS PLUGGED IN OR NOT
- ENSURE 120V IS PRESENT AT OUTLET
- ENGAGE WATER SUPPLY AND CHECK TEMP SETTING
- IF UNIT IS SPITTING WHILE ENGAGED, TYPICALLY THERE IS A HOLE IN THE INTERNAL TANK AND IT SHOULD BE REPLACED.
- IF LEAKING AT SPOUT, CHECK O-RINGS AT SPOUT CONNECTION.
REPLACEMENT
- UNPLUG UNIT/TURN POWER OFF.
- TURN OFF WATER SUPPLY TO UNIT
- ON SS UNIT, UN CLIP AND DETACH ALL 3 LINES TO TO OF UNIT. THIS CAN VARY ON DIFFERENT INSTA HOT MODELS. I.E; FRANKE, LIL BUTLER ETC.
- REMOVE UNIT AND REPLACE WITH SAME UNIT.
- ATTACH AND HANG NEW TANK.
- ATTACH OLD 3 WATER LINES FROM EXISTING SPOUT TO TANK.
- TURN WATER BACK ON AND FILL TANK WITH PURE STREAM COMING OUT OF SPOUT TO CLEAR OUT ANY AIR.
- PLUG UNIT IT/TURN ON POWER - THIS IS DONE AFTER FILLING TO PREVENT DRY FIRE OF UNIT.