-======Repair/​Replace Insta-Hot====== 
- 
-====REPAIR===== 
- 
-  - IDENTIFY IF UNIT IS PLUGGED IN OR NOT 
-  - ENSURE 120V IS PRESENT AT OUTLET 
-  - ENGAGE WATER SUPPLY AND CHECK TEMP SETTING ​ 
-  - IF UNIT IS SPITTING WHILE ENGAGED, TYPICALLY THERE IS A HOLE IN THE INTERNAL TANK AND IT SHOULD BE REPLACED. ​ 
-  - IF LEAKING AT SPOUT, CHECK O-RINGS AT SPOUT CONNECTION. ​ 
- 
-====REPLACEMENT==== 
- 
-  - UNPLUG UNIT/TURN POWER OFF.  
-  - TURN OFF WATER SUPPLY TO UNIT 
-  - ON SS UNIT, UN CLIP AND DETACH ALL 3 LINES TO TO OF UNIT. THIS CAN VARY ON DIFFERENT INSTA HOT MODELS. I.E; FRANKE, LIL BUTLER ETC. 
-  - REMOVE UNIT AND REPLACE WITH SAME UNIT.  
-  - ATTACH AND HANG NEW TANK.  
-  - ATTACH OLD 3 WATER LINES FROM EXISTING SPOUT TO TANK.  
-  - TURN WATER BACK ON AND FILL TANK WITH PURE STREAM COMING OUT OF SPOUT TO CLEAR OUT ANY AIR.  
-  - PLUG UNIT IT/TURN ON POWER - THIS IS DONE AFTER FILLING TO PREVENT DRY FIRE OF UNIT. 
  