-======Repair/​Replace Faucet====== 
- 
-====REPAIR==== 
- 
-  - IF DRIPPING/​LEAKING,​ CHECK WATER PRESSURE TO THE HOUSE TO ENSURE UNDER 80PSI. IF OVER 80 PSI, REFER TO WATER PRESSURE PROTOCOL (PRV & EXPANSION TANK). 
-  - IF UNDER 80PSI, ESTABLISH IF FAUCET IS LEAKING AT HANDLE/​SPOUT ABOVE OR CONNECTIONS UNDERNEATH. ​ 
-  - TURN OFF WATER TO THE FIXTURE AND ANGLE STOPS UNDERNEATH. ​ 
-  - DISASSEMBLE HANDLES WITH CRESCENT WRENCH/​ALLEN WRENCHES AS APPLICABLE AND EXAMINE CARTRIDGES AND SEALS FOR COMPROMISE. 
-  - REPLACE CARTRIDGE, SPRINGS, O-RINGS AS NECESSARY AND APPLY PLUIMBERS GREASE AS NECESSARY. 
-  - REASSEMBLE, TURN WATER ON AND CHECK FOR LEAKS AND CHECK OPERATION. ​ 
- 
-====REPLACEMENT==== ​   ​ 
- 
-  - TURN OFF HOT AND COLD WATER TO FAUCET AT ANGLE STOPS CAREFULLY. 
-  - DISCONNECT SUPPLY LINES FROM ANGLE STOPS. ​ 
-  - REMOVE SUPPLY LINES FROM FAUCET CONNECTIONS UNDERNEATH, I.E; LAVATORY AND KITCHEN FAUCETS. ​ 
-  - REMOVE RETAINING NUTS 
-  - REMOVE FAUCET 
-  - CLEAR SURFACE AS BEST AS POSSIBLE AND AS CLOSE TO NEW AS POSSIBLE WITH A NON ACIDIC SURFACE CLEANER. ​ 
-  - SET NEW FAUCET SQUARELY IN PLACE AND TIGHTEN RETAINING NUTS UNDERNEATH WITH A BASIN WRENCH. 
-  - INSTALL NEW SUPPLY LINES AND CONNECT TO ANGLE STOPS. BE SURE TO APPLY A SMALL AMOUNT OF PIPE DOPE TO THREADS ON FAUCET BASE AND ANGLE STOP BEFORE SECURING SUPPLY LINES. ​ 
-  - SECURE SUPPLY LINES AND TURN ON ANGLE STOPS CAREFULLY AND SLOWLY. ​ 
-  - TURN ON FAUCET AND CHECK FOR LEAKS. ​ 
  